Self-contained air-cooled through-the-wall units are the most economical and easiest to install—no licensed HVAC/R technician required.  The evaporator side blows cold air into the cellar while the condenser side absorbs warmth from the cellar and exhausts it into the adjacent room.  Self-contained units tend to be noisier than either ducted or split units.  There are models for wall thicknesses ranging from 2X4 framing up to 20” thick insulated concrete or block; room-to-room indoor models as well as interior-to-exterior models.  If warm-side conditions permit, cellars as small as 150 cu. ft and up to 2000 cu. ft. will accept a through-the-wall unit.  

 

It’s time to get serious about your fine wine collection. Wine Guardian patented Through-the-Wall (TTW) wine cellar cooling units bring exceptional airflow and optimal temperature control to ensure you enjoy 100% of the flavors of your wine.

TTW units match maximum efficiency with quiet operation to create peak wine storage conditions for your small- to mid-sized wine room or wine wall

TTW018 - THROUGH THE WALL WINE CELLAR COOLING UNIT - 60HZ

This through-the-wall wine air conditioning unit can be installed on your own without the support of a contractor and is best suited for smaller commercial and residential wine cellars and wine cabinets.

The TTW018 is a 60Hz system, which is standard in most of North America (incl. USA & Canada). Unit capacity is 981 – 1845 BTUH.

TTW009 - THROUGH THE WALL WINE CELLAR COOLING UNIT - 60 HZ

This through-the-wall wine cellar cooling unit is ideal for small home wine cellars and wine cabinets.

The TTW009 is a 60Hz system, which is standard in most of North America (incl. USA & Canada). Unit capacity is 250 – 999 BTUH.

TTW009H - THROUGH THE WALL WINE CELLAR COOLING UNIT WITH HEATER

This Through-The-Wall wine conditioning system with an electric heater is ideal for small residential wine cellars in colder climates in which the wine cellar dips below proper storage conditions.

The TTW009H is a 60Hz system, which is standard in most of North America (incl. USA & Canada). Unit capacity is 250 – 999 BTUH.

TTW018H - THROUGH THE WALL WINE CELLAR COOLING UNIT WITH HEATER

This through-the-wall wine air conditioning unit with heater is ideal for smaller residential wine cellars. Heating is beneficial for wine rooms in places where temperatures around the wine room may drop below desired storage conditions.

The TTW018H is a 60Hz system, which is standard in most of North America (incl. USA & Canada). Unit capacity is 981 – 1845 BTUH.

WHISPER KOOL

Through the wall, wine cooling units

Self Contained systems are designed to mount between the studs of an existing wall. One end of the system blows cool air in to the cellar, and the other end exhausts the heat from the cellar into an area adjacent to the cellar.

2000

Cellar Size:
Approx. 300 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier (each wine cellar is unique and has specific cooling requirements; heat load calculations should always be performed prior to selecting a cooling unit)

BTU/h Rating @85°F condenser intake: 1453
Dimensions:
17.5″L x 14.25″W x 15.75″H

3000

Cellar Size:
Approx. 650 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier (each wine cellar is unique and has specific cooling requirements; heat load calculations should always be performed prior to selecting a cooling unit)

BTU/h Rating:
@85°F condenser intake: 2049
Dimensions:
17.5″L x 14.25″W x 15.75″H

8000

Cellar Size:
Approx. 2000 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier (each wine cellar is unique and has specific cooling requirements; heat load calculations should always be performed prior to selecting a cooling unit)

BTU/h Rating:
@85°F condenser intake: 4241
Dimensions:
21.64″L x 14.25″W x 22.56″H

CELLARCOOL

Through the wall, wine cooling units - Optimum Series

The Optimum Series systems incorporate the latest and greatest features in wine cooling into their design, at an affordable price. Advanced blower fans replace axial fans, which accelerates the ow of cold air in your cellar at an even distribution. A condensate evaporator has been added to effectively manage condensate produced by the coil (up to 3 ounces of condensate per hour). The unit also utilizes a smart-metering TXV valve that efficiently manages the ow of refrigeration through the system to ensure optimal performance. In order to keep your cellar at 55°F, the condenser intake should not exceed 85°F. This makes interior installation ideal for Optimum Series units. Our Ultimate Series units are better suited for exterior installations.

2200

Cellar Size: 300
BTUh: (w/85°F air entering condenser coil) 1453
Dimensions: 17.5”L x 14.25”W x 15.75”H

3300

Cellar Size: 650
BTUh: (w/85°F air entering the condenser coil) 2049
Dimensions: 17.5”L x 14.25”W x 15.75”H

4400

Cellar Size: 1000
BTUh: (w/85°F air entering the condenser coil) 2253
Dimensions: 17.5”L x 14.25”W x 15.75”H

2200

Cellar Size: 300
BTUh: (w/85°F air entering condenser coil) 1453
Dimensions: 17.5”L x 14.25”W x 15.75”H

CELLARCOOL

Through the wall, wine cooling units - CX Series

The CX Standard –Thru-Wall System has a dynamic air flow allowing for excellent circulation of air throughout the cellar,“best-in-class” 30 degree temperature variance, and the digital controller with system safety management and anti-frost features. Furthermore, these units are a direct replacement for the Breezaire and Wine Mate Thru-Wall units.

CX2200/CX2200-RPC

Cellar Size: 300
BTUh: (w/85°F air entering condenser coil) 1453
Dimensions: 14.25”W x 13.25”H x 16.38”D

CX3300/CX3300-RPC

Cellar Size: 650
BTUh: (w/85°F air entering the condenser coil) 2049
Dimensions:14.25”W x 19.75”H x 21.63”D

CX4400/CX4400-RPC

Cellar Size: 1000
BTUh: (w/85°F air entering the condenser coil) 2962
Dimensions:17.5”L x 14.25”W x 15.75”H

CX8800/CX8800-RPC

Cellar Size: 2000
BTUh: (w/85°F air entering condenser coil )4754
Dimensions: 16.25”W x 22”H x 22.25”D

CELLARCOOL

Through the wall, wine cooling units - Ultimate Series

The Ultimate – Thru Wall System is designed for installation in hotter locations or climates with a full 55 degrees temperature variance. These units can mount thru-the-wall like the CX Self Contained units or can be remote mounted outside the cellar with duct runs up to 25 ft away.

Ultimate 3300/Ultimate 3300-R

Cellar Size: 300
BTUh: (w/85°F air entering condenser coil) 1453
Dimensions:28”L x 14.25”W x 15.75”H

Ultimate 4400/ Ultimate 4400-R

Cellar Size:1250
BTUh: (w/85°F air entering the condenser coil) 3175
Dimensions:28”L x 14.25”W x 15.75”H

Ultimate 8800/ Ultimate 8800-R

Cellar Size:2000
BTUh: (w/85°F air entering the condenser coil) 6131
Dimensions: 28”L x 14.25”W x 22.5”H